Neodecanoic acid SDS
SECTION 1: Identification of the substance/mixture and of the company/undertaking
Product identifier
- Product name: Neodecanoic acid
- CAS: 26896-20-8
Relevant identified uses of the substance or mixture and uses advised against
- Relevant identified uses: For R&D use only. Not for medicinal, household or other use.
- Uses advised against: none
Company Identification
- Company:Chemicalbook.in
- Address:5 vasavi Layout Basaveswara Nilayam Pragathi Nagar Hyderabad, India -500090
- Telephone:+91 9550333722
SECTION 2: Hazards identification
Classification of the substance or mixture
Not classified.
GHS label elements, including precautionary statements
- Signal word No signal word
none
none
none
none
none
Other hazards which do not result in classification
no data available
SECTION 3: Composition/information on ingredients
Substance
- Chemical name: Neodecanoic acid
- Common names and synonyms: Neodecanoic acid
- CAS number: 26896-20-8
- EC number: 248-093-9
- Concentration: 100%
SECTION 4: First aid measures
Description of necessary first-aid measures
Fresh air, rest.
Rinse and then wash skin with water and soap.
Rinse with plenty of water (remove contact lenses if easily possible).
Do NOT induce vomiting. Seek medical attention if you feel unwell.
Most important symptoms/effects, acute and delayed
Irritating to eyes and respiratory tract in high concentrations. May cause hair disorder or damage. (USCG, 1999)
Indication of immediate medical attention and special treatment needed, if necessary
no data available
SECTION 5: Firefighting measures
Suitable extinguishing media
Fire Extinguishing Agents: Water spray, alcohol foam or dry chemical. (USCG, 1999)
Specific hazards arising from the chemical
Special Hazards of Combustion Products: Flammable toxic gas may be released, if thermally decomposed. (USCG, 1999)
Special protective actions for fire-fighters
Use water spray, foam, powder, carbon dioxide. In case of fire: keep drums, etc., cool by spraying with water.
SECTION 6: Accidental release measures
Personal precautions, protective equipment and emergency procedures
Personal protection: filter respirator for organic gases and vapours adapted to the airborne concentration of the substance. Do NOT let this chemical enter the environment. Collect leaking liquid in sealable plastic containers. Absorb remaining liquid in sand or inert absorbent. Then store and dispose of according to local regulations.
Environmental precautions
Personal protection: filter respirator for organic gases and vapours adapted to the airborne concentration of the substance. Do NOT let this chemical enter the environment. Collect leaking liquid in sealable plastic containers. Absorb remaining liquid in sand or inert absorbent. Then store and dispose of according to local regulations.
Methods and materials for containment and cleaning up
Collect and arrange disposal. Keep the chemical in suitable and closed containers for disposal. Remove all sources of ignition. Use spark-proof tools and explosion-proof equipment. Adhered or collected material should be promptly disposed of, in accordance with appropriate laws and regulations.
SECTION 7: Handling and storage
Precautions for safe handling
NO open flames. Above 94°C use a closed system and ventilation. Handling in a well ventilated place. Wear suitable protective clothing. Avoid contact with skin and eyes. Avoid formation of dust and aerosols. Use non-sparking tools. Prevent fire caused by electrostatic discharge steam.
Conditions for safe storage, including any incompatibilities
Separated from strong oxidants. Ventilation along the floor. Store in an area without drain or sewer access.
SECTION 8: Exposure controls/personal protection
Control parameters
no data available
no data available
Appropriate engineering controls
Ensure adequate ventilation. Handle in accordance with good industrial hygiene and safety practice. Set up emergency exits and the risk-elimination area.
Individual protection measures, such as personal protective equipment (PPE)
Wear safety spectacles.
Protective gloves.
Use ventilation.
no data available
SECTION 9: Physical and chemical properties and safety characteristics
-
Physical state:
Neodecanoic acid is a colorless liquid. (USCG, 1999)
-
Colour:
no data available
-
Odour:
no data available
-
Melting point/freezing point:
34-36?°C(lit.)
-
Boiling point or initial boiling point and boiling range:
262.1°C at 760 mmHg
-
Flammability:
Combustible.
-
Lower and upper explosion limit/flammability limit:
no data available
-
Flash point:
118.6°C
-
Auto-ignition temperature:
no data available
-
Decomposition temperature:
no data available
-
pH:
no data available
-
Kinematic viscosity:
45 mm2/s at 20°C
-
Solubility:
in water, g/100ml at 25°C: 0.025 (very poor)
-
Partition coefficient n-octanol/water:
3.6 (calculated)
-
Vapour pressure:
0.00329mmHg at 25°C
-
Density and/or relative density:
0.913 g/cm3
-
Relative vapour density:
(air = 1): 5.9
-
Particle characteristics:
no data available
SECTION 10: Stability and reactivity
Reactivity
Reacts with strong oxidants strong oxidants. This generates fire and explosion hazard. Attacks metal.
Chemical stability
no data available
Possibility of hazardous reactions
NEODECANOIC ACID is a carboxylic acid. Carboxylic acids donate hydrogen ions if a base is present to accept them. They react in this way with all bases, both organic (for example, the amines) and inorganic. Their reactions with bases, called "neutralizations", are accompanied by the evolution of substantial amounts of heat. Neutralization between an acid and a base produces water plus a salt. Carboxylic acids in aqueous solution and liquid or molten carboxylic acids can react with active metals to form gaseous hydrogen and a metal salt. Such reactions occur in principle for solid carboxylic acids as well, but are slow if the solid acid remains dry. Even "insoluble" carboxylic acids may absorb enough water from the air and dissolve sufficiently in it to corrode or dissolve iron, steel, and aluminum parts and containers. Carboxylic acids, like other acids, react with cyanide salts to generate gaseous hydrogen cyanide. The reaction is slower for dry, solid carboxylic acids. Insoluble carboxylic acids react with solutions of cyanides to cause the release of gaseous hydrogen cyanide. Flammable and/or toxic gases and heat are generated by the reaction of carboxylic acids with diazo compounds, dithiocarbamates, isocyanates, mercaptans, nitrides, and sulfides. Carboxylic acids, especially in aqueous solution, also react with sulfites, nitrites, thiosulfates (to give H2S and SO3), dithionites (SO2), to generate flammable and/or toxic gases and heat. Their reaction with carbonates and bicarbonates generates a harmless gas (carbon dioxide) but still heat. Like other organic compounds, carboxylic acids can be oxidized by strong oxidizing agents and reduced by strong reducing agents. These reactions generate heat. A wide variety of products is possible. Like other acids, carboxylic acids may initiate polymerization reactions; like other acids, they often catalyze (increase the rate of) chemical reactions.
Conditions to avoid
no data available
Incompatible materials
no data available
Hazardous decomposition products
no data available
SECTION 11: Toxicological information
Acute toxicity
- Oral: no data available
- Inhalation: no data available
- Dermal: no data available
Skin corrosion/irritation
no data available
Serious eye damage/irritation
no data available
Respiratory or skin sensitization
no data available
Germ cell mutagenicity
no data available
Carcinogenicity
no data available
Reproductive toxicity
no data available
STOT-single exposure
The substance is irritating to the eyes. If swallowed the substance may cause vomiting and could result in aspiration pneumonitis.
STOT-repeated exposure
Repeated or prolonged contact with skin may cause dermatitis dermatitis.
Aspiration hazard
No indication can be given about the rate at which a harmful concentration of this substance in the air is reached.
SECTION 12: Ecological information
Toxicity
- Toxicity to fish: no data available
- Toxicity to daphnia and other aquatic invertebrates: no data available
- Toxicity to algae: no data available
- Toxicity to microorganisms: no data available
Persistence and degradability
no data available
Bioaccumulative potential
no data available
Mobility in soil
no data available
Other adverse effects
no data available
SECTION 13: Disposal considerations
Disposal methods
The material can be disposed of by removal to a licensed chemical destruction plant or by controlled incineration with flue gas scrubbing. Do not contaminate water, foodstuffs, feed or seed by storage or disposal. Do not discharge to sewer systems.
Containers can be triply rinsed (or equivalent) and offered for recycling or reconditioning. Alternatively, the packaging can be punctured to make it unusable for other purposes and then be disposed of in a sanitary landfill. Controlled incineration with flue gas scrubbing is possible for combustible packaging materials.
SECTION 14: Transport information
UN Number
ADR/RID: Not dangerous goods. (For reference only, please check.)
IMDG: Not dangerous goods. (For reference only, please check.)
IATA: Not dangerous goods. (For reference only, please check.)
UN Proper Shipping Name
ADR/RID: Not dangerous goods. (For reference only, please check.)
IMDG: Not dangerous goods. (For reference only, please check.)
IATA: Not dangerous goods. (For reference only, please check.)
Transport hazard class(es)
ADR/RID: Not dangerous goods. (For reference only, please check.)
IMDG: Not dangerous goods. (For reference only, please check.)
IATA: Not dangerous goods. (For reference only, please check.)
Packing group, if applicable
ADR/RID: Not dangerous goods. (For reference only, please check.)
IMDG: Not dangerous goods. (For reference only, please check.)
IATA: Not dangerous goods. (For reference only, please check.)
Environmental hazards
ADR/RID: No
IMDG: No
IATA: No
Special precautions for user
no data available
Transport in bulk according to IMO instruments
no data available
SECTION 15: Regulatory information
Safety, health and environmental regulations specific for the product in question
SECTION 16: Other information
Abbreviations and acronyms
- CAS: Chemical Abstracts Service
- ADR: European Agreement concerning the International Carriage of Dangerous Goods by Road
- RID: Regulation concerning the International Carriage of Dangerous Goods by Rail
- IMDG: International Maritime Dangerous Goods
- IATA: International Air Transportation Association
- TWA: Time Weighted Average
- STEL: Short term exposure limit
- LC50: Lethal Concentration 50%
- LD50: Lethal Dose 50%
- EC50: Effective Concentration 50%
References
- IPCS - The International Chemical Safety Cards (ICSC), website: http://www.ilo.org/dyn/icsc/showcard.home
- HSDB - Hazardous Substances Data Bank, website: https://toxnet.nlm.nih.gov/newtoxnet/hsdb.htm
- IARC - International Agency for Research on Cancer, website: http://www.iarc.fr/
- eChemPortal - The Global Portal to Information on Chemical Substances by OECD, website: http://www.echemportal.org/echemportal/index?pageID=0&request_locale=en
- CAMEO Chemicals, website: http://cameochemicals.noaa.gov/search/simple
- ChemIDplus, website: http://chem.sis.nlm.nih.gov/chemidplus/chemidlite.jsp
- ERG - Emergency Response Guidebook by U.S. Department of Transportation, website: http://www.phmsa.dot.gov/hazmat/library/erg
- Germany GESTIS-database on hazard substance, website: http://www.dguv.de/ifa/gestis/gestis-stoffdatenbank/index-2.jsp
- ECHA - European Chemicals Agency, website: https://echa.europa.eu/
Other Information
Neodecanoic acid, with CAS number 26896-20-8, includes different isomers. Some are listed under the synonyms.Health effects of exposure to the substance have not been investigated adequately.Refer for medical attention if breathing difficulties and/or fever develop.