7-methyl-3-methyleneocta-1,6-diene SDS
SECTION 1: Identification of the substance/mixture and of the company/undertaking
Product identifier
- Product name: 7-methyl-3-methyleneocta-1,6-diene
- CAS: 123-35-3
Relevant identified uses of the substance or mixture and uses advised against
- Relevant identified uses: For R&D use only. Not for medicinal, household or other use.
- Uses advised against: none
Company Identification
- Company:Chemicalbook.in
- Address:5 vasavi Layout Basaveswara Nilayam Pragathi Nagar Hyderabad, India -500090
- Telephone:+91 9550333722
SECTION 2: Hazards identification
Classification of the substance or mixture
Not classified.
GHS label elements, including precautionary statements
-
Pictogram(s)
- Signal word Danger
H226 Flammable liquid and vapour
H304 May be fatal if swallowed and enters airways
H315 Causes skin irritation
H319 Causes serious eye irritation
H400 Very toxic to aquatic life
H411 Toxic to aquatic life with long lasting effects
none
none
none
none
Other hazards which do not result in classification
no data available
SECTION 3: Composition/information on ingredients
Substance
- Chemical name: 7-methyl-3-methyleneocta-1,6-diene
- Common names and synonyms: 7-methyl-3-methyleneocta-1,6-diene
- CAS number: 123-35-3
- EC number: 204-622-5
- Concentration: 100%
SECTION 4: First aid measures
Description of necessary first-aid measures
Move the victim into fresh air. If breathing is difficult, give oxygen. If not breathing, give artificial respiration and consult a doctor immediately. Do not use mouth to mouth resuscitation if the victim ingested or inhaled the chemical.
Take off contaminated clothing immediately. Wash off with soap and plenty of water. Consult a doctor.
Rinse with pure water for at least 15 minutes. Consult a doctor.
Rinse mouth with water. Do not induce vomiting. Never give anything by mouth to an unconscious person. Call a doctor or Poison Control Center immediately.
Most important symptoms/effects, acute and delayed
May be harmful by inhalation, ingestion or skin absorption. (USCG, 1999)
Indication of immediate medical attention and special treatment needed, if necessary
Immediate first aid: Ensure that adequate decontamination has been carried out. If patient is not breathing, start artificial respiration, preferably with a demand valve resuscitator, bag-valve-mask device, or pocket mask, as trained. Perform CPR if necessary. Immediately flush contaminated eyes with gently flowing water. Do not induce vomiting. If vomiting occurs, lean patient forward or place on the left side (head-down position, if possible) to maintain an open airway and prevent aspiration. Keep patient quiet and maintain normal body temperature. Obtain medical attention. Poisons A and B
SECTION 5: Firefighting measures
Suitable extinguishing media
If material on fire or involved in a fire: Use water in flooding quantities as fog. Cool all affected containers with flooding quantities of water. Apply water from as far a distance as possible. Solid streams of water may be ineffective. Use "alcohol" foam, dry chemical, or carbon dioxide.
Specific hazards arising from the chemical
Special Hazards of Combustion Products: Vapor may travel considerable distance to a source of ignition and flashback. (USCG, 1999)
Special protective actions for fire-fighters
Wear self-contained breathing apparatus for firefighting if necessary.
SECTION 6: Accidental release measures
Personal precautions, protective equipment and emergency procedures
Avoid dust formation. Avoid breathing mist, gas or vapours.Avoid contacting with skin and eye. Use personal protective equipment.Wear chemical impermeable gloves. Ensure adequate ventilation.Remove all sources of ignition. Evacuate personnel to safe areas.Keep people away from and upwind of spill/leak.
Environmental precautions
Prevent further spillage or leakage if it is safe to do so. Do not let the chemical enter drains. Discharge into the environment must be avoided.
Methods and materials for containment and cleaning up
Collect and arrange disposal. Keep the chemical in suitable and closed containers for disposal. Remove all sources of ignition. Use spark-proof tools and explosion-proof equipment. Adhered or collected material should be promptly disposed of, in accordance with appropriate laws and regulations.
SECTION 7: Handling and storage
Precautions for safe handling
Handling in a well ventilated place. Wear suitable protective clothing. Avoid contact with skin and eyes. Avoid formation of dust and aerosols. Use non-sparking tools. Prevent fire caused by electrostatic discharge steam.
Conditions for safe storage, including any incompatibilities
Store in a cool place from which light and air are excluded.
SECTION 8: Exposure controls/personal protection
Control parameters
no data available
no data available
Appropriate engineering controls
Ensure adequate ventilation. Handle in accordance with good industrial hygiene and safety practice. Set up emergency exits and the risk-elimination area.
Individual protection measures, such as personal protective equipment (PPE)
Wear tightly fitting safety goggles with side-shields conforming to EN 166(EU) or NIOSH (US).
Wear fire/flame resistant and impervious clothing. Handle with gloves. Gloves must be inspected prior to use. Wash and dry hands. The selected protective gloves have to satisfy the specifications of EU Directive 89/686/EEC and the standard EN 374 derived from it.
If the exposure limits are exceeded, irritation or other symptoms are experienced, use a full-face respirator.
no data available
SECTION 9: Physical and chemical properties and safety characteristics
-
Physical state:
Liquid. Liquid.
-
Colour:
Colourless slightly amber coloured.
-
Odour:
Pleasant
-
Melting point/freezing point:
< -80 °C. Atm. press.:1 atm.
-
Boiling point or initial boiling point and boiling range:
>= 164 - <= 165 °C. Atm. press.:760 mm Hg.
-
Flammability:
no data available
-
Lower and upper explosion limit/flammability limit:
no data available
-
Flash point:
Ca. 45 °C. Atm. press.:Ca. 1 atm.
-
Auto-ignition temperature:
265 °C. Atm. press.:100 248 Pa. Remarks:Experiment 1: Ignition delay: 12 seconds.;260 °C. Atm. press.:100 129 Pa. Remarks:Experiment 2: Ignition delay: 12 seconds.;259 °C. Atm. press.:10 089 Pa. Remarks:Experiment 3: Ignition delay: 22 seconds.
-
Decomposition temperature:
no data available
-
pH:
no data available
-
Kinematic viscosity:
no data available
-
Solubility:
Soluble in alcohol, chloroform, ether, glacial acetic acid
-
Partition coefficient n-octanol/water:
log Pow = 4.82. Temperature:30 °C. Remarks:+/- 0.01.
-
Vapour pressure:
251 Pa. Temperature:25 °C. Remarks:± 35 Pa.
-
Density and/or relative density:
0.793. Temperature:20 °C.
-
Relative vapour density:
4.7 (vs air)
-
Particle characteristics:
no data available
SECTION 10: Stability and reactivity
Reactivity
no data available
Chemical stability
no data available
Possibility of hazardous reactions
A flammable liquid.The unsaturated aliphatic hydrocarbons, such as MYRCENE, are generally much more reactive than the alkanes. Strong oxidizers may react vigorously with them. Reducing agents can react exothermically to release gaseous hydrogen. In the presence of various catalysts (such as acids) or initiators, compounds in this class can undergo very exothermic addition polymerization reactions. Many of these compounds undergo autoxidation upon exposure to the air to form explosive peroxides. Violent explosions have occurred at low temperatures in ammonia synthesis gas units. These explosions have been traced to the addition products of dienes and oxides of nitrogen, produced from the interaction of nitrogen oxide and oxygen [Bretherick, 1995].
Conditions to avoid
no data available
Incompatible materials
no data available
Hazardous decomposition products
When heated to decomposition it emits acrid smoke and irritating fumes.
SECTION 11: Toxicological information
Acute toxicity
- Oral: LD50 Rat oral >5000 mg/kg bw
- Inhalation: no data available
- Dermal: no data available
Skin corrosion/irritation
no data available
Serious eye damage/irritation
no data available
Respiratory or skin sensitization
no data available
Germ cell mutagenicity
no data available
Carcinogenicity
no data available
Reproductive toxicity
no data available
STOT-single exposure
no data available
STOT-repeated exposure
no data available
Aspiration hazard
no data available
SECTION 12: Ecological information
Toxicity
- Toxicity to fish: LC50 - Cyprinus carpio - 96 h. Remarks:Average concentration obtained in a WAF prepared at a loading rate of 10 mg/l.
- Toxicity to daphnia and other aquatic invertebrates: EC50 - Daphnia magna - 1.47 mg/L - 48 h.
- Toxicity to algae: EC50 - Pseudokirchneriella subcapitata (previous names: Raphidocelis subcapitata, Selenastrum capricornutum) - 0.342 mg/L - 72 h.
- Toxicity to microorganisms: no data available
Persistence and degradability
AEROBIC: Myrcene has been observed to undergo biodegradation in aerated lagoons, rate constant not specified(1). Myrcene, present at 100 mg/L, reached 82-92% of its theoretical BOD in 2 weeks using an activated sludge inoculum at 30 mg/L and the Japanese MITI test(2) which classifies the compound as readily biodegradable. Monoterpene compounds similar in structure to myrcene (limonene, pinene, terpinene, terpinolene) were readily degraded in aerobic batch experiments using forest soil and enriched cultures(3).
Bioaccumulative potential
An estimated BCF of 334 was calculated in fish for myrcene(SRC), using a log Kow of 4.33(1) and a regression-derived equation(2). According to a classification scheme(3), this BCF suggests the potential for bioconcentration in aquatic organisms is high(SRC), provided the compound is not metabolized by the organism(SRC).
Mobility in soil
Using a structure estimation method based on molecular connectivity indices(1), the Koc of myrcene can be estimated to be 1074(SRC). According to a classification scheme(2), this estimated Koc value suggests that myrcene is expected to have low mobility in soil.
Other adverse effects
no data available
SECTION 13: Disposal considerations
Disposal methods
The material can be disposed of by removal to a licensed chemical destruction plant or by controlled incineration with flue gas scrubbing. Do not contaminate water, foodstuffs, feed or seed by storage or disposal. Do not discharge to sewer systems.
Containers can be triply rinsed (or equivalent) and offered for recycling or reconditioning. Alternatively, the packaging can be punctured to make it unusable for other purposes and then be disposed of in a sanitary landfill. Controlled incineration with flue gas scrubbing is possible for combustible packaging materials.
SECTION 14: Transport information
UN Number
ADR/RID: Not dangerous goods. (For reference only, please check.)
IMDG: Not dangerous goods. (For reference only, please check.)
IATA: Not dangerous goods. (For reference only, please check.)
UN Proper Shipping Name
ADR/RID: Not dangerous goods. (For reference only, please check.)
IMDG: Not dangerous goods. (For reference only, please check.)
IATA: Not dangerous goods. (For reference only, please check.)
Transport hazard class(es)
ADR/RID: Not dangerous goods. (For reference only, please check.)
IMDG: Not dangerous goods. (For reference only, please check.)
IATA: Not dangerous goods. (For reference only, please check.)
Packing group, if applicable
ADR/RID: Not dangerous goods. (For reference only, please check.)
IMDG: Not dangerous goods. (For reference only, please check.)
IATA: Not dangerous goods. (For reference only, please check.)
Environmental hazards
ADR/RID: No
IMDG: No
IATA: No
Special precautions for user
no data available
Transport in bulk according to IMO instruments
no data available
SECTION 15: Regulatory information
Safety, health and environmental regulations specific for the product in question
SECTION 16: Other information
Abbreviations and acronyms
- CAS: Chemical Abstracts Service
- ADR: European Agreement concerning the International Carriage of Dangerous Goods by Road
- RID: Regulation concerning the International Carriage of Dangerous Goods by Rail
- IMDG: International Maritime Dangerous Goods
- IATA: International Air Transportation Association
- TWA: Time Weighted Average
- STEL: Short term exposure limit
- LC50: Lethal Concentration 50%
- LD50: Lethal Dose 50%
- EC50: Effective Concentration 50%
References
- IPCS - The International Chemical Safety Cards (ICSC), website: http://www.ilo.org/dyn/icsc/showcard.home
- HSDB - Hazardous Substances Data Bank, website: https://toxnet.nlm.nih.gov/newtoxnet/hsdb.htm
- IARC - International Agency for Research on Cancer, website: http://www.iarc.fr/
- eChemPortal - The Global Portal to Information on Chemical Substances by OECD, website: http://www.echemportal.org/echemportal/index?pageID=0&request_locale=en
- CAMEO Chemicals, website: http://cameochemicals.noaa.gov/search/simple
- ChemIDplus, website: http://chem.sis.nlm.nih.gov/chemidplus/chemidlite.jsp
- ERG - Emergency Response Guidebook by U.S. Department of Transportation, website: http://www.phmsa.dot.gov/hazmat/library/erg
- Germany GESTIS-database on hazard substance, website: http://www.dguv.de/ifa/gestis/gestis-stoffdatenbank/index-2.jsp
- ECHA - European Chemicals Agency, website: https://echa.europa.eu/