Oxidizing solids, Category 1
Acute toxicity - Category 4, Oral
Skin irritation, Category 2
Eye irritation, Category 2
H271 May cause fire or explosion; strong oxidizer
H302 Harmful if swallowed
H315 Causes skin irritation
H319 Causes serious eye irritation
P210 Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
P220 Keep away from clothing and other combustible materials.
P280 Wear protective gloves/protective clothing/eye protection/face protection/hearing protection/...
P283 Wear fire resistant or flame retardant clothing.
P264 Wash ... thoroughly after handling.
P270 Do not eat, drink or smoke when using this product.
P306+P360 IF ON CLOTHING: Rinse immediately contaminated clothing and skin with plenty of water before removing clothes.
P371+P380+P375 In case of major fire and large quantities: Evacuate area. Fight fire remotely due to the risk of explosion.
P370+P378 In case of fire: Use ... to extinguish.
P301+P317 IF SWALLOWED: Get medical help.
P330 Rinse mouth.
P302+P352 IF ON SKIN: Wash with plenty of water/...
P321 Specific treatment (see ... on this label).
P332+P317 If skin irritation occurs: Get medical help.
P362+P364 Take off contaminated clothing and wash it before reuse.
P305+P351+P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
P420 Store separately.
P501 Dispose of contents/container to an appropriate treatment and disposal facility in accordance with applicable laws and regulations, and product characteristics at time of disposal.
no data available
Move the victim into fresh air. If breathing is difficult, give oxygen. If not breathing, give artificial respiration and consult a doctor immediately. Do not use mouth to mouth resuscitation if the victim ingested or inhaled the chemical.
Take off contaminated clothing immediately. Wash off with soap and plenty of water. Consult a doctor.
Rinse with pure water for at least 15 minutes. Consult a doctor.
Rinse mouth with water. Do not induce vomiting. Never give anything by mouth to an unconscious person. Call a doctor or Poison Control Center immediately.
Inhalation of dust irritates mucous membranes. Ingestion of large amounts may be fatal; immediate symptoms include adominal pains, nausea and vomiting, diarrhea, pallor, blueness, shortness of breath, unconsciousness. Contact with eyes or skin causes irritation. (USCG, 1999)
Basic treatment: Establish a patent airway. Suction if necessary. Watch for signs of respiratory insufficiency and assist ventilations if necessary. Administer oxygen by nonrebreather mask at 10 to 15 L/min. Monitor for pulmonary edema and treat if necessary . Monitor for shock and treat if necessary . For eye contamination, flush eyes immediately with water. Irrigate each eye continuously with normal saline during transport . Do not use emetics. For ingestion, rinse mouth and administer 5 ml/kg up to 200 ml of water for dilution if the patient can swallow, has a strong gag reflex, and does not drool . Magnesium and Related Compounds
If material on fire or involved in fire: Flood with water. Cool all affected containers with flooding quantities of water. Apply water from as far a distance as possible.
Behavior in Fire: Can form explosive mixture with combustible material or finely powdered metals. Increases the intensity of fires. (USCG, 1999)
Wear self-contained breathing apparatus for firefighting if necessary.
Avoid dust formation. Avoid breathing mist, gas or vapours.Avoid contacting with skin and eye. Use personal protective equipment.Wear chemical impermeable gloves. Ensure adequate ventilation.Remove all sources of ignition. Evacuate personnel to safe areas.Keep people away from and upwind of spill/leak.
Prevent further spillage or leakage if it is safe to do so. Do not let the chemical enter drains. Discharge into the environment must be avoided.
Immediately remove & carefully dispose of any spilled perchlorate.
Handling in a well ventilated place. Wear suitable protective clothing. Avoid contact with skin and eyes. Avoid formation of dust and aerosols. Use non-sparking tools. Prevent fire caused by electrostatic discharge steam.
Protect against physical damage. store in dry place of noncombustible construction, separate from combustible, org, readily oxidizable materials, & acids.
no data available
no data available
Ensure adequate ventilation. Handle in accordance with good industrial hygiene and safety practice. Set up emergency exits and the risk-elimination area.
Wear tightly fitting safety goggles with side-shields conforming to EN 166(EU) or NIOSH (US).
Wear fire/flame resistant and impervious clothing. Handle with gloves. Gloves must be inspected prior to use. Wash and dry hands. The selected protective gloves have to satisfy the specifications of EU Directive 89/686/EEC and the standard EN 374 derived from it.
If the exposure limits are exceeded, irritation or other symptoms are experienced, use a full-face respirator.
no data available
Magnesium perchlorate is a white crystalline solid. Strongly absorbs water from air and dissolves in it. Accordingly, used as a regenerable drying agent. May explode under prolonged exposure to heat or fire.
White, granular, or flaky powder
Odorless
251°C
Decomposes above 482.0° F (USCG, 1999)
no data available
no data available
no data available
no data available
no data available
no data available
no data available
99.3 G/100 CC OF H20 & 23.96 G/100 CC OF ALCOHOL, EACH AT 25 DEG C
no data available
no data available
2.21 (18 °C)
no data available
no data available
Deliquescent. Water soluble
no data available
POWERFUL OXIDIZING MATERIAL; MIXTURES WITH COMBUSTIBLE ORG OR OTHER EASILY OXIDIZABLE MATERIALS...ARE IGNITED READILY BY FRICTION OR HEAT.MAGNESIUM PERCHLORATE is a strong oxidizing agent. Decomposes at 185-190°C [Hawley]. Noncombustible but accelerates the burning of combustible materials. If large quantities are involved in the fire or the combustible material is finely divided an explosion may result. Avoid contact with mineral acids because of the danger of explosion. In the preparation of anhydrous dimethyl sulfoxide by vacuum distillation from anhydrous magnesium perchlorate, an explosion occurred [MCA Case History 1187, 1966]. Drying ethylene oxide with magnesium perchlorate resulted in an explosion [NSC Newsletter. Chem. Soc. 1959]. Magnesium perchlorate used in drying hydrocarbons exploded when heated to 220°C [Ind. & Eng. News 17:70. 1939]. As soon as trimethyl phosphite contacted a small amount of magnesium perchlorate in a flask, there was a flash and an explosion that shattered the flask [Allison 1968].
no data available
The anhydrous salt /of magnesium perchlorate/ which had been used for drying unsaturated hydrocarbons exploded on heating to 220 deg C for reactivation. The need to avoid contact with acidic materials is stressed. Magnesium perchlorate, anhydrous salt
When heated to decomposition it emits toxic fumes of /magnesium oxide and hydrogen chloride/.
no data available
no data available
no data available
no data available
no data available
no data available
no data available
no data available
no data available
no data available
no data available
no data available
no data available
The material can be disposed of by removal to a licensed chemical destruction plant or by controlled incineration with flue gas scrubbing. Do not contaminate water, foodstuffs, feed or seed by storage or disposal. Do not discharge to sewer systems.
Containers can be triply rinsed (or equivalent) and offered for recycling or reconditioning. Alternatively, the packaging can be punctured to make it unusable for other purposes and then be disposed of in a sanitary landfill. Controlled incineration with flue gas scrubbing is possible for combustible packaging materials.
ADR/RID: UN1475 (For reference only, please check.)
IMDG: UN1475 (For reference only, please check.)
IATA: UN1475 (For reference only, please check.)
ADR/RID: MAGNESIUM PERCHLORATE (For reference only, please check.)
IMDG: MAGNESIUM PERCHLORATE (For reference only, please check.)
IATA: MAGNESIUM PERCHLORATE (For reference only, please check.)
ADR/RID: 5.1 (For reference only, please check.)
IMDG: 5.1 (For reference only, please check.)
IATA: 5.1 (For reference only, please check.)
ADR/RID: II (For reference only, please check.)
IMDG: II (For reference only, please check.)
IATA: II (For reference only, please check.)
ADR/RID: No
IMDG: No
IATA: No
no data available
no data available