1,1-DICHLORO-1-FLUOROTHANE SDS
SECTION 1: Identification of the substance/mixture and of the company/undertaking
Product identifier
- Product name: 1,1-DICHLORO-1-FLUOROTHANE
- CAS: 1717-00-6
Relevant identified uses of the substance or mixture and uses advised against
- Relevant identified uses: For R&D use only. Not for medicinal, household or other use.
- Uses advised against: none
Company Identification
- Company:Chemicalbook.in
- Address:5 vasavi Layout Basaveswara Nilayam Pragathi Nagar Hyderabad, India -500090
- Telephone:+91 9550333722
SECTION 2: Hazards identification
Classification of the substance or mixture
Hazardous to the aquatic environment, long-term (Chronic) - Category Chronic 3
GHS label elements, including precautionary statements
- Signal word No signal word
H412 Harmful to aquatic life with long lasting effects
P273 Avoid release to the environment.
none
none
P501 Dispose of contents/container to an appropriate treatment and disposal facility in accordance with applicable laws and regulations, and product characteristics at time of disposal.
Other hazards which do not result in classification
no data available
SECTION 3: Composition/information on ingredients
Substance
- Chemical name: 1,1-DICHLORO-1-FLUOROTHANE
- Common names and synonyms: 1,1-DICHLORO-1-FLUOROTHANE
- CAS number: 1717-00-6
- EC number: 605-613-2
- Concentration: 100%
SECTION 4: First aid measures
Description of necessary first-aid measures
Fresh air, rest. Refer for medical attention.
Rinse and then wash skin with water and soap.
Rinse with plenty of water (remove contact lenses if easily possible).
Do NOT induce vomiting.
Most important symptoms/effects, acute and delayed
no data available
Indication of immediate medical attention and special treatment needed, if necessary
no data available
SECTION 5: Firefighting measures
Suitable extinguishing media
Use dry chemical, carbon dioxide or alcohol-resistant foam.
Specific hazards arising from the chemical
Gives off irritating or toxic fumes (or gases) in a fire.
Special protective actions for fire-fighters
Use water spray, foam, powder, carbon dioxide. In case of fire: keep drums, etc., cool by spraying with water.
SECTION 6: Accidental release measures
Personal precautions, protective equipment and emergency procedures
Personal protection: self-contained breathing apparatus. Do NOT let this chemical enter the environment. Ventilation. Collect leaking liquid in sealable containers. Absorb remaining liquid in sand or inert absorbent. Carefully collect remainder. Then store and dispose of according to local regulations.
Environmental precautions
Prevent further spillage or leakage if it is safe to do so. Do not let the chemical enter drains. Discharge into the environment must be avoided.
Methods and materials for containment and cleaning up
Collect and arrange disposal. Keep the chemical in suitable and closed containers for disposal. Remove all sources of ignition. Use spark-proof tools and explosion-proof equipment. Adhered or collected material should be promptly disposed of, in accordance with appropriate laws and regulations.
SECTION 7: Handling and storage
Precautions for safe handling
NO contact with hot surfaces. Handling in a well ventilated place. Wear suitable protective clothing. Avoid contact with skin and eyes. Avoid formation of dust and aerosols. Use non-sparking tools. Prevent fire caused by electrostatic discharge steam.
Conditions for safe storage, including any incompatibilities
Separated from strong acids. Cool. Keep in a well-ventilated room. Store in an area without drain or sewer access.
SECTION 8: Exposure controls/personal protection
Control parameters
no data available
no data available
Appropriate engineering controls
Ensure adequate ventilation. Handle in accordance with good industrial hygiene and safety practice. Set up emergency exits and the risk-elimination area.
Individual protection measures, such as personal protective equipment (PPE)
Wear safety goggles.
Protective gloves.
Use closed system or ventilation.
no data available
SECTION 9: Physical and chemical properties and safety characteristics
-
Physical state:
Liquid.
-
Colour:
no data available
-
Odour:
no data available
-
Melting point/freezing point:
-103.5 °C.
-
Boiling point or initial boiling point and boiling range:
32 °C. Atm. press.:101.3 kPa.
-
Flammability:
no data available
-
Lower and upper explosion limit/flammability limit:
no data available
-
Flash point:
Atm. press.:32.
-
Auto-ignition temperature:
532 °C.
-
Decomposition temperature:
no data available
-
pH:
no data available
-
Kinematic viscosity:
no data available
-
Solubility:
In water: 4 000 mg/L. Temperature:20 °C.
-
Partition coefficient n-octanol/water:
log Pow = 2.3. Temperature:22 °C.
-
Vapour pressure:
76 300 Pa. Temperature:25 °C.;47 100 Pa. Temperature:12.7 °C.
-
Density and/or relative density:
1.24. Temperature:20 °C.
-
Relative vapour density:
no data available
-
Particle characteristics:
no data available
SECTION 10: Stability and reactivity
Reactivity
no data available
Chemical stability
no data available
Possibility of hazardous reactions
The vapour is heavier than air and may accumulate in lowered spaces causing a deficiency of oxygen.Decomposes on contact with hot surfaces or flames. This produces hydrogen chloride, hydrogen fluoride and phosgene. Reacts with strong acids.
Conditions to avoid
no data available
Incompatible materials
no data available
Hazardous decomposition products
no data available
SECTION 11: Toxicological information
Acute toxicity
- Oral: LD50 - (male/female) - > 5 000 mg/kg bw.
- Inhalation: LC50 - (male/female) - 295 mg/L air.
- Dermal: LD50 - (male/female) - > 2 000 mg/kg bw.
Skin corrosion/irritation
no data available
Serious eye damage/irritation
no data available
Respiratory or skin sensitization
no data available
Germ cell mutagenicity
no data available
Carcinogenicity
no data available
Reproductive toxicity
no data available
STOT-single exposure
The substance is mildly irritating to the eyes. The substance may cause effects on the central nervous system and cardiovascular system. This may result in lowering of consciousness and cardiac disorders. Suffocation.
STOT-repeated exposure
no data available
Aspiration hazard
On loss of containment this substance can cause serious risk of suffocation when in confined areas.
SECTION 12: Ecological information
Toxicity
- Toxicity to fish: LC50 - Danio rerio (previous name: Brachydanio rerio) - 158 mg/L - 96 h.
- Toxicity to daphnia and other aquatic invertebrates: EC50 - other aquatic crustacea: - 31.2 mg/L - 48 h.
- Toxicity to algae: EC50 - Pseudokirchneriella subcapitata (previous names: Raphidocelis subcapitata, Selenastrum capricornutum) - > 44 mg/L - 72 h.
- Toxicity to microorganisms: no data available
Persistence and degradability
no data available
Bioaccumulative potential
no data available
Mobility in soil
no data available
Other adverse effects
no data available
SECTION 13: Disposal considerations
Disposal methods
The material can be disposed of by removal to a licensed chemical destruction plant or by controlled incineration with flue gas scrubbing. Do not contaminate water, foodstuffs, feed or seed by storage or disposal. Do not discharge to sewer systems.
Containers can be triply rinsed (or equivalent) and offered for recycling or reconditioning. Alternatively, the packaging can be punctured to make it unusable for other purposes and then be disposed of in a sanitary landfill. Controlled incineration with flue gas scrubbing is possible for combustible packaging materials.
SECTION 14: Transport information
UN Number
ADR/RID: Not dangerous goods. (For reference only, please check.)
IMDG: Not dangerous goods. (For reference only, please check.)
IATA: Not dangerous goods. (For reference only, please check.)
UN Proper Shipping Name
ADR/RID: Not dangerous goods. (For reference only, please check.)
IMDG: Not dangerous goods. (For reference only, please check.)
IATA: Not dangerous goods. (For reference only, please check.)
Transport hazard class(es)
ADR/RID: Not dangerous goods. (For reference only, please check.)
IMDG: Not dangerous goods. (For reference only, please check.)
IATA: Not dangerous goods. (For reference only, please check.)
Packing group, if applicable
ADR/RID: Not dangerous goods. (For reference only, please check.)
IMDG: Not dangerous goods. (For reference only, please check.)
IATA: Not dangerous goods. (For reference only, please check.)
Environmental hazards
ADR/RID: No
IMDG: No
IATA: No
Special precautions for user
no data available
Transport in bulk according to IMO instruments
no data available
SECTION 15: Regulatory information
Safety, health and environmental regulations specific for the product in question
SECTION 16: Other information
Abbreviations and acronyms
- CAS: Chemical Abstracts Service
- ADR: European Agreement concerning the International Carriage of Dangerous Goods by Road
- RID: Regulation concerning the International Carriage of Dangerous Goods by Rail
- IMDG: International Maritime Dangerous Goods
- IATA: International Air Transportation Association
- TWA: Time Weighted Average
- STEL: Short term exposure limit
- LC50: Lethal Concentration 50%
- LD50: Lethal Dose 50%
- EC50: Effective Concentration 50%
References
- IPCS - The International Chemical Safety Cards (ICSC), website: http://www.ilo.org/dyn/icsc/showcard.home
- HSDB - Hazardous Substances Data Bank, website: https://toxnet.nlm.nih.gov/newtoxnet/hsdb.htm
- IARC - International Agency for Research on Cancer, website: http://www.iarc.fr/
- eChemPortal - The Global Portal to Information on Chemical Substances by OECD, website: http://www.echemportal.org/echemportal/index?pageID=0&request_locale=en
- CAMEO Chemicals, website: http://cameochemicals.noaa.gov/search/simple
- ChemIDplus, website: http://chem.sis.nlm.nih.gov/chemidplus/chemidlite.jsp
- ERG - Emergency Response Guidebook by U.S. Department of Transportation, website: http://www.phmsa.dot.gov/hazmat/library/erg
- Germany GESTIS-database on hazard substance, website: http://www.dguv.de/ifa/gestis/gestis-stoffdatenbank/index-2.jsp
- ECHA - European Chemicals Agency, website: https://echa.europa.eu/
Other Information
High concentrations in the air cause a deficiency of oxygen with the risk of unconsciousness or death.Check oxygen content before entering the area.