Barite (Ba(SO4)) SDS
SECTION 1: Identification of the substance/mixture and of the company/undertaking
Product identifier
- Product name: Barite (Ba(SO4))
- CAS: 13462-86-7
Relevant identified uses of the substance or mixture and uses advised against
- Relevant identified uses: For R&D use only. Not for medicinal, household or other use.
- Uses advised against: none
Company Identification
- Company:Chemicalbook.in
- Address:5 vasavi Layout Basaveswara Nilayam Pragathi Nagar Hyderabad, India -500090
- Telephone:+91 9550333722
SECTION 2: Hazards identification
Classification of the substance or mixture
Not classified.
GHS label elements, including precautionary statements
- Signal word No signal word
none
none
none
none
none
Other hazards which do not result in classification
no data available
SECTION 3: Composition/information on ingredients
Substance
- Chemical name: Barite (Ba(SO4))
- Common names and synonyms: Barite (Ba(SO4))
- CAS number: 13462-86-7
- EC number: 236-664-5
- Concentration: 100%
SECTION 4: First aid measures
Description of necessary first-aid measures
Fresh air, rest.
Remove contaminated clothes. Rinse skin with plenty of water or shower.
First rinse with plenty of water for several minutes (remove contact lenses if easily possible), then refer for medical attention.
Rinse mouth.
Most important symptoms/effects, acute and delayed
Exposure Routes: inhalation, skin and/or eye contact Symptoms: Irritation eyes, nose, upper respiratory system; benign pneumoconiosis (baritosis) Target Organs: Eyes, respiratory system (NIOSH, 2016)
Indication of immediate medical attention and special treatment needed, if necessary
Immediate first aid: Ensure that adequate decontamination has been carried out. If patient is not breathing, start artificial respiration, preferably with a demand-valve resuscitator, bag-valve-mask device, or pocket mask, as trained. Perform CPR as necessary. Immediately flush contaminated eyes with gently flowing water. Do not induce vomiting. If vomiting occurs, lean patient forward or place on left side (head-down position, if possible) to maintain an open airway and prevent aspiration. Keep patient quiet and maintain normal body temperature. Obtain medical attention. Barium and Related Compounds
SECTION 5: Firefighting measures
Suitable extinguishing media
Use dry chemical, carbon dioxide, water spray, or alcohol foam extinguishers ... If material or contaminated runoff enters waterways, notify downstream users of potentially contaminated waters. Notify local health and fire officials and pollution control agencies. From a secure, explosion-proof location, use water spray to cool exposed containers. If cooling streams are ineffective (venting sound increases in volume and pitch, tank discolors or shows any signs of deforming), withdraw immediately to a secure position ... The only respirators recommended for fire fighting are self-contained breathing apparatuses that have full facepieces and are operated in a pressure-demand or other positive-pressure mode.
Specific hazards arising from the chemical
Excerpt from ERG Guide 154 [Substances - Toxic and/or Corrosive (Non-Combustible)]: Non-combustible, substance itself does not burn but may decompose upon heating to produce corrosive and/or toxic fumes. Some are oxidizers and may ignite combustibles (wood, paper, oil, clothing, etc.). Contact with metals may evolve flammable hydrogen gas. Containers may explode when heated. For electric vehicles or equipment, ERG Guide 147 (lithium ion batteries) or ERG Guide 138 (sodium batteries) should also be consulted. (ERG, 2016)
Special protective actions for fire-fighters
Wear self-contained breathing apparatus for firefighting if necessary.
SECTION 6: Accidental release measures
Personal precautions, protective equipment and emergency procedures
Avoid dust formation. Avoid breathing mist, gas or vapours.Avoid contacting with skin and eye. Use personal protective equipment.Wear chemical impermeable gloves. Ensure adequate ventilation.Remove all sources of ignition. Evacuate personnel to safe areas.Keep people away from and upwind of spill/leak.
Environmental precautions
Sweep spilled substance into covered containers. If appropriate, moisten first to prevent dusting. Personal protection: particulate filter respirator adapted to the airborne concentration of the substance.
Methods and materials for containment and cleaning up
Spill handling: evacuate and restrict persons not wearing protective equipment from area of spill or leak until cleanup is complete. Remove all ignition sources. Collect powdered material in the most convenient and safe manner and deposit in sealed containers. Ventilate area of spill or lead after clean-up is complete. It may be necessary to contain and dispose of this chemical as a hazardous waste. If material or contaminated runoff enters waterways, notify downstream users of potentially contaminated waters. Contact your Department of Environmental Protection or your regional office of the federal EPA for specific recommendations.
SECTION 7: Handling and storage
Precautions for safe handling
Handling in a well ventilated place. Wear suitable protective clothing. Avoid contact with skin and eyes. Avoid formation of dust and aerosols. Use non-sparking tools. Prevent fire caused by electrostatic discharge steam.
Conditions for safe storage, including any incompatibilities
Store at 25 deg C (77 deg F); excursions permitted to 15 to 30 deg C (59 to 86 deg F)
SECTION 8: Exposure controls/personal protection
Control parameters
| Component | Barite (Ba(SO4)) |
|---|---|
| CAS No. | 13462-86-7 |
|
Recommended Exposure Limit: 10 Hour Time-Weighted Average: 10 mg/cu m, total particulate. Recommended Exposure Limit: 10 Hour Time-Weighted average: 5 mg/cu m, respirable fraction. |
no data available
Appropriate engineering controls
Ensure adequate ventilation. Handle in accordance with good industrial hygiene and safety practice. Set up emergency exits and the risk-elimination area.
Individual protection measures, such as personal protective equipment (PPE)
Wear tightly fitting safety goggles with side-shields conforming to EN 166(EU) or NIOSH (US).
Wear fire/flame resistant and impervious clothing. Handle with gloves. Gloves must be inspected prior to use. Wash and dry hands. The selected protective gloves have to satisfy the specifications of EU Directive 89/686/EEC and the standard EN 374 derived from it.
If the exposure limits are exceeded, irritation or other symptoms are experienced, use a full-face respirator.
no data available
SECTION 9: Physical and chemical properties and safety characteristics
-
Physical state:
Barium sulfate is a white or yellowish odorless powder or small crystals. Mp: 1580°C (with decomposition). Density: 4.25 -4.5 g cm-3. Insoluble in water, dilute acids, alcohol. Soluble in hot concentrated sulfuric acid. Used as a weighting mud in oil-drilling, in paints, paper coatings, linoleum, textiles, rubber. Administered internally ("barium cocktail") as a radio-opaque diagnostic aid.
-
Colour:
Fine, heavy powder or polymorphous crystals
-
Odour:
Odorless
-
Melting point/freezing point:
1580°C
-
Boiling point or initial boiling point and boiling range:
330°C at 760 mmHg
-
Flammability:
Noncombustible Solid
-
Lower and upper explosion limit/flammability limit:
no data available
-
Flash point:
no data available
-
Auto-ignition temperature:
no data available
-
Decomposition temperature:
1600°C
-
pH:
5% suspension in water is neutral to litmus paper
-
Kinematic viscosity:
no data available
-
Solubility:
0.0002 % at 64° F (NIOSH, 2016)
-
Partition coefficient n-octanol/water:
no data available
-
Vapour pressure:
0 mm Hg (approx) (NIOSH, 2016)
-
Density and/or relative density:
4.25 to 4.5 (NIOSH, 2016)
-
Relative vapour density:
no data available
-
Particle characteristics:
no data available
SECTION 10: Stability and reactivity
Reactivity
Reacts violently with aluminium powder.
Chemical stability
no data available
Possibility of hazardous reactions
Not combustible.BARIUM SULFATE is non-combustible and non-toxic. Emits toxic sulfur oxides when heated to decomposition. Can act as an oxidizing agent, but usually does not. Reacts with reducing agents such as potassium, phosphorus or aluminum (heating with aluminum can cause an explosion).
Conditions to avoid
no data available
Incompatible materials
Phosphorus, aluminum [Aluminum in the presence of heat can cause an explosion.]
Hazardous decomposition products
When heated to decomposition it emits toxic fumes of /sulfur oxides/.
SECTION 11: Toxicological information
Acute toxicity
- Oral: LD50 Rat oral approx 307,000 mg/kg bw
- Inhalation: no data available
- Dermal: no data available
Skin corrosion/irritation
no data available
Serious eye damage/irritation
no data available
Respiratory or skin sensitization
no data available
Germ cell mutagenicity
no data available
Carcinogenicity
no data available
Reproductive toxicity
no data available
STOT-single exposure
no data available
STOT-repeated exposure
no data available
Aspiration hazard
no data available
SECTION 12: Ecological information
Toxicity
- Toxicity to fish: no data available
- Toxicity to daphnia and other aquatic invertebrates: EC50; Species: Daphnia magna (Water Flea); Conditions: freshwater, static, 11.5-14.5 deg C, pH 7.2-7.8, dissolved oxygen 5.2-6.5 mg/L; Concentration: 52820 ug/L (43200-68140 ug/L) for 24 hr; Effect: intoxicaiton, immobilization
- Toxicity to algae: no data available
- Toxicity to microorganisms: no data available
Persistence and degradability
no data available
Bioaccumulative potential
no data available
Mobility in soil
no data available
Other adverse effects
no data available
SECTION 13: Disposal considerations
Disposal methods
The material can be disposed of by removal to a licensed chemical destruction plant or by controlled incineration with flue gas scrubbing. Do not contaminate water, foodstuffs, feed or seed by storage or disposal. Do not discharge to sewer systems.
Containers can be triply rinsed (or equivalent) and offered for recycling or reconditioning. Alternatively, the packaging can be punctured to make it unusable for other purposes and then be disposed of in a sanitary landfill. Controlled incineration with flue gas scrubbing is possible for combustible packaging materials.
SECTION 14: Transport information
UN Number
ADR/RID: no data available
IMDG: no data available
IATA: no data available
UN Proper Shipping Name
ADR/RID: no data available
IMDG: no data available
IATA: no data available
Transport hazard class(es)
ADR/RID: no data available
IMDG: no data available
IATA: no data available
Packing group, if applicable
ADR/RID: no data available
IMDG: no data available
IATA: no data available
Environmental hazards
ADR/RID: No
IMDG: No
IATA: No
Special precautions for user
no data available
Transport in bulk according to IMO instruments
no data available
SECTION 15: Regulatory information
Safety, health and environmental regulations specific for the product in question
SECTION 16: Other information
Abbreviations and acronyms
- CAS: Chemical Abstracts Service
- ADR: European Agreement concerning the International Carriage of Dangerous Goods by Road
- RID: Regulation concerning the International Carriage of Dangerous Goods by Rail
- IMDG: International Maritime Dangerous Goods
- IATA: International Air Transportation Association
- TWA: Time Weighted Average
- STEL: Short term exposure limit
- LC50: Lethal Concentration 50%
- LD50: Lethal Dose 50%
- EC50: Effective Concentration 50%
References
- IPCS - The International Chemical Safety Cards (ICSC), website: http://www.ilo.org/dyn/icsc/showcard.home
- HSDB - Hazardous Substances Data Bank, website: https://toxnet.nlm.nih.gov/newtoxnet/hsdb.htm
- IARC - International Agency for Research on Cancer, website: http://www.iarc.fr/
- eChemPortal - The Global Portal to Information on Chemical Substances by OECD, website: http://www.echemportal.org/echemportal/index?pageID=0&request_locale=en
- CAMEO Chemicals, website: http://cameochemicals.noaa.gov/search/simple
- ChemIDplus, website: http://chem.sis.nlm.nih.gov/chemidplus/chemidlite.jsp
- ERG - Emergency Response Guidebook by U.S. Department of Transportation, website: http://www.phmsa.dot.gov/hazmat/library/erg
- Germany GESTIS-database on hazard substance, website: http://www.dguv.de/ifa/gestis/gestis-stoffdatenbank/index-2.jsp
- ECHA - European Chemicals Agency, website: https://echa.europa.eu/