Antimony pentafluoride SDS
SECTION 1: Identification of the substance/mixture and of the company/undertaking
Product identifier
- Product name: Antimony pentafluoride
- CAS: 7783-70-2
Relevant identified uses of the substance or mixture and uses advised against
- Relevant identified uses: For R&D use only. Not for medicinal, household or other use.
- Uses advised against: none
Company Identification
- Company:Chemicalbook.in
- Address:5 vasavi Layout Basaveswara Nilayam Pragathi Nagar Hyderabad, India -500090
- Telephone:+91 9550333722
SECTION 2: Hazards identification
Classification of the substance or mixture
Hazardous to the aquatic environment, long-term (Chronic) - Category Chronic 3
GHS label elements, including precautionary statements
- Signal word No signal word
H412 Harmful to aquatic life with long lasting effects
P273 Avoid release to the environment.
none
none
P501 Dispose of contents/container to an appropriate treatment and disposal facility in accordance with applicable laws and regulations, and product characteristics at time of disposal.
Other hazards which do not result in classification
no data available
SECTION 3: Composition/information on ingredients
Substance
- Chemical name: Antimony pentafluoride
- Common names and synonyms: Antimony pentafluoride
- CAS number: 7783-70-2
- EC number: 232-021-8
- Concentration: 100%
SECTION 4: First aid measures
Description of necessary first-aid measures
Fresh air, rest. Half-upright position. Refer immediately for medical attention. See Notes.
Remove contaminated clothes. Rinse skin with plenty of water or shower. Refer immediately for medical attention. Apply calcium gluconate to the burn areas.
Rinse with plenty of water for several minutes (remove contact lenses if easily possible). Refer immediately for medical attention.
Rinse mouth. Do NOT induce vomiting. Refer immediately for medical attention.
Most important symptoms/effects, acute and delayed
The compound is irritating to eyes, skin, and lungs. Contact with eyes or skin causes severe burns. The compound is extremely toxic with a probable oral lethal dose of 5-50 mg/kg or between 7 drops and one teaspoonful for a 150 pound person (antimony salts). (EPA, 1998)
Indication of immediate medical attention and special treatment needed, if necessary
Distribution in rats after chronic poisoning by inhalation of antimony pentafluoride showed high antimony concn in blood. levels in liver, kidneys, spleen and pancreas were similar. the antimony was retained for a long time and could be detected in organs under examination one month after experiment discontinued.
SECTION 5: Firefighting measures
Suitable extinguishing media
Approach fire from upwind to avoid hazardous vapors & toxic decomposition products. Use dry chemical, carbon dioxide or flooding quantities of water as spray on fire involved material.
Specific hazards arising from the chemical
Reacts violently with water, to form poisonous hydrogen fluoride fumes. If confined and wet can cause explosion. May cause fire in contact with combustible material. Hazardous polymerization may not occur. (EPA, 1998)
Special protective actions for fire-fighters
Use powder, carbon dioxide. NO water. NO hydrous agents. In case of fire: keep drums, etc., cool by spraying with water. NO direct contact with water.
SECTION 6: Accidental release measures
Personal precautions, protective equipment and emergency procedures
Evacuate danger area! Consult an expert! Personal protection: complete protective clothing including self-contained breathing apparatus. Collect leaking and spilled liquid in sealable containers as far as possible. Do NOT wash away into sewer. Do NOT absorb in saw-dust or other combustible absorbents. Do NOT let this chemical enter the environment. Then store and dispose of according to local regulations.
Environmental precautions
Evacuate danger area! Consult an expert! Personal protection: complete protective clothing including self-contained breathing apparatus. Collect leaking and spilled liquid in sealable containers as far as possible. Do NOT wash away into sewer. Do NOT absorb in saw-dust or other combustible absorbents. Do NOT let this chemical enter the environment. Then store and dispose of according to local regulations.
Methods and materials for containment and cleaning up
Collect and arrange disposal. Keep the chemical in suitable and closed containers for disposal. Remove all sources of ignition. Use spark-proof tools and explosion-proof equipment. Adhered or collected material should be promptly disposed of, in accordance with appropriate laws and regulations.
SECTION 7: Handling and storage
Precautions for safe handling
Handling in a well ventilated place. Wear suitable protective clothing. Avoid contact with skin and eyes. Avoid formation of dust and aerosols. Use non-sparking tools. Prevent fire caused by electrostatic discharge steam.
Conditions for safe storage, including any incompatibilities
Separated from combustible substances, reducing agents and food and feedstuffs. Dry. Well closed. Keep in a well-ventilated room. Do NOT store or transport in containers made from metal or glass. Provision to contain effluent from fire extinguishing. Store in an area without drain or sewer access.Store in a cool, dry, well-ventilated location. Outside or detached storage is preferred. Separate from organic or siliceous materials.
SECTION 8: Exposure controls/personal protection
Control parameters
TLV: 0.5 mg/m3, as TWA.MAK: carcinogen category: 2; germ cell mutagen group: 3B
no data available
Appropriate engineering controls
Ensure adequate ventilation. Handle in accordance with good industrial hygiene and safety practice. Set up emergency exits and the risk-elimination area.
Individual protection measures, such as personal protective equipment (PPE)
Wear face shield or eye protection in combination with breathing protection.
Protective gloves. Protective clothing.
Use ventilation, local exhaust or breathing protection.
no data available
SECTION 9: Physical and chemical properties and safety characteristics
-
Physical state:
Antimony pentafluoride is a colorless, oily liquid. Fumes irritate the eyes and mucous membranes. Toxic. Corrosive to metals and tissue. Extremely dangerous to tissue; its burns may be followed by gangrene. Only shipped in cylinders. Under prolonged exposure to heat cylinders may violently rupture and rocket. Used to make other chemicals as well as a catalyst in the manufacture of other chemicals.
-
Colour:
MODERATELY VISCOUS LIQUID
-
Odour:
SHARP ODOR
-
Melting point/freezing point:
7°C(lit.)
-
Boiling point or initial boiling point and boiling range:
148-150°C(lit.)
-
Flammability:
Not combustible but enhances combustion of other substances. Gives off irritating or toxic fumes (or gases) in a fire.
-
Lower and upper explosion limit/flammability limit:
no data available
-
Flash point:
149.5°C
-
Auto-ignition temperature:
no data available
-
Decomposition temperature:
no data available
-
pH:
no data available
-
Kinematic viscosity:
0.768 cp @ 24.4 deg C (est)
-
Solubility:
Sol in potassium fluoride (KF), liquid sulfur dioxide
-
Partition coefficient n-octanol/water:
no data available
-
Vapour pressure:
10 mm Hg ( 25 °C)
-
Density and/or relative density:
2.993g/mLat 25°C(lit.)
-
Relative vapour density:
2.2 (vs air)
-
Particle characteristics:
no data available
SECTION 10: Stability and reactivity
Reactivity
Decomposes on heating and on burning. This produces toxic and corrosive fumes including antimony and fluorine. Reacts violently with water. This produces toxic and corrosive hydrogen fluoride (see ICSC 0283). Attacks many metals. This produces a combustible/explosive gas (hydrogen - see ICSC 0001).
Chemical stability
no data available
Possibility of hazardous reactions
ANTIMONY PENTAFLUORIDE is strongly acidic. Reacts vigorously with bases. When heated to decomposition, it emits highly toxic fumes of fluorides and metallic antimony. Reacts with ammonia to form a diammoniate.
Conditions to avoid
no data available
Incompatible materials
Reacts violently with water. also forms a solid dihydrate, which reacts violently with more water to form a clear soln.
Hazardous decomposition products
When heated to decomp it emits very toxic fumes of /hydrogen fluoride/ and antimony.
SECTION 11: Toxicological information
Acute toxicity
- Oral: no data available
- Inhalation: no data available
- Dermal: no data available
Skin corrosion/irritation
no data available
Serious eye damage/irritation
no data available
Respiratory or skin sensitization
no data available
Germ cell mutagenicity
no data available
Carcinogenicity
A4; Not classifiable as a human carcinogen. Fluorides, as F
Reproductive toxicity
no data available
STOT-single exposure
Corrosive. Inhalation may cause severe swelling of the throat. This may result in asphyxia. Inhalation may cause lung oedema, but only after initial corrosive effects on eyes and/or airways have become manifest. Exposure at high levels could cause severe lung damage. See Notes. Medical observation is indicated.
STOT-repeated exposure
The substance may have effects on the cardiovascular system and respiratory tract. This may result in impaired functions.
Aspiration hazard
A harmful contamination of the air can be reached very quickly on evaporation of this substance at 20°C.
SECTION 12: Ecological information
Toxicity
- Toxicity to fish: no data available
- Toxicity to daphnia and other aquatic invertebrates: no data available
- Toxicity to algae: no data available
- Toxicity to microorganisms: no data available
Persistence and degradability
no data available
Bioaccumulative potential
no data available
Mobility in soil
no data available
Other adverse effects
no data available
SECTION 13: Disposal considerations
Disposal methods
The material can be disposed of by removal to a licensed chemical destruction plant or by controlled incineration with flue gas scrubbing. Do not contaminate water, foodstuffs, feed or seed by storage or disposal. Do not discharge to sewer systems.
Containers can be triply rinsed (or equivalent) and offered for recycling or reconditioning. Alternatively, the packaging can be punctured to make it unusable for other purposes and then be disposed of in a sanitary landfill. Controlled incineration with flue gas scrubbing is possible for combustible packaging materials.
SECTION 14: Transport information
UN Number
ADR/RID: UN1732 (For reference only, please check.)
IMDG: UN1732 (For reference only, please check.)
IATA: UN1732 (For reference only, please check.)
UN Proper Shipping Name
ADR/RID: ANTIMONY PENTAFLUORIDE (For reference only, please check.)
IMDG: ANTIMONY PENTAFLUORIDE (For reference only, please check.)
IATA: ANTIMONY PENTAFLUORIDE (For reference only, please check.)
Transport hazard class(es)
ADR/RID: 8 (For reference only, please check.)
IMDG: 8 (For reference only, please check.)
IATA: 8 (For reference only, please check.)
Packing group, if applicable
ADR/RID: II (For reference only, please check.)
IMDG: II (For reference only, please check.)
IATA: II (For reference only, please check.)
Environmental hazards
ADR/RID: No
IMDG: No
IATA: No
Special precautions for user
no data available
Transport in bulk according to IMO instruments
no data available
SECTION 15: Regulatory information
Safety, health and environmental regulations specific for the product in question
SECTION 16: Other information
Abbreviations and acronyms
- CAS: Chemical Abstracts Service
- ADR: European Agreement concerning the International Carriage of Dangerous Goods by Road
- RID: Regulation concerning the International Carriage of Dangerous Goods by Rail
- IMDG: International Maritime Dangerous Goods
- IATA: International Air Transportation Association
- TWA: Time Weighted Average
- STEL: Short term exposure limit
- LC50: Lethal Concentration 50%
- LD50: Lethal Dose 50%
- EC50: Effective Concentration 50%
References
- IPCS - The International Chemical Safety Cards (ICSC), website: http://www.ilo.org/dyn/icsc/showcard.home
- HSDB - Hazardous Substances Data Bank, website: https://toxnet.nlm.nih.gov/newtoxnet/hsdb.htm
- IARC - International Agency for Research on Cancer, website: http://www.iarc.fr/
- eChemPortal - The Global Portal to Information on Chemical Substances by OECD, website: http://www.echemportal.org/echemportal/index?pageID=0&request_locale=en
- CAMEO Chemicals, website: http://cameochemicals.noaa.gov/search/simple
- ChemIDplus, website: http://chem.sis.nlm.nih.gov/chemidplus/chemidlite.jsp
- ERG - Emergency Response Guidebook by U.S. Department of Transportation, website: http://www.phmsa.dot.gov/hazmat/library/erg
- Germany GESTIS-database on hazard substance, website: http://www.dguv.de/ifa/gestis/gestis-stoffdatenbank/index-2.jsp
- ECHA - European Chemicals Agency, website: https://echa.europa.eu/
Other Information
Reacts violently with fire extinguishing agents such as water.The symptoms of lung oedema often do not become manifest until a few hours have passed and they are aggravated by physical effort.Rest and medical observation are therefore essential.Immediate administration of an appropriate inhalation therapy by a doctor or a person authorized by him/her, should be considered.See ICSC 0283.Specific treatment is necessary in case of poisoning with this substance; the appropriate means with instructions must be available.