Norflurane SDS
SECTION 1: Identification of the substance/mixture and of the company/undertaking
Product identifier
- Product name: Norflurane
- CAS: 811-97-2
Relevant identified uses of the substance or mixture and uses advised against
- Relevant identified uses: For R&D use only. Not for medicinal, household or other use.
- Uses advised against: none
Company Identification
- Company:Chemicalbook.in
- Address:5 vasavi Layout Basaveswara Nilayam Pragathi Nagar Hyderabad, India -500090
- Telephone:+91 9550333722
SECTION 2: Hazards identification
Classification of the substance or mixture
Not classified.
GHS label elements, including precautionary statements
-
Pictogram(s)
- Signal word Warning
H280 Contains gas under pressure; may explode if heated
none
none
none
none
Other hazards which do not result in classification
no data available
SECTION 3: Composition/information on ingredients
Substance
- Chemical name: Norflurane
- Common names and synonyms: Norflurane
- CAS number: 811-97-2
- EC number: 212-377-0
- Concentration: 100%
SECTION 4: First aid measures
Description of necessary first-aid measures
Fresh air, rest. Refer for medical attention.
ON FROSTBITE: rinse with plenty of water, do NOT remove clothes.
Rinse with pure water for at least 15 minutes. Consult a doctor.
Rinse mouth with water. Do not induce vomiting. Never give anything by mouth to an unconscious person. Call a doctor or Poison Control Center immediately.
Most important symptoms/effects, acute and delayed
Excerpt from ERG Guide 126 [Gases - Compressed or Liquefied (Including Refrigerant Gases)]: Vapors may cause dizziness or asphyxiation without warning. Vapors from liquefied gas are initially heavier than air and spread along ground. Contact with gas or liquefied gas may cause burns, severe injury and/or frostbite. Fire may produce irritating, corrosive and/or toxic gases. (ERG, 2016)
Indication of immediate medical attention and special treatment needed, if necessary
Immediate first aid: Ensure that adequate decontamination has been carried out. If patient is not breathing, start artificial respiration, preferably with a demand-valve resuscitator, bag-valve-mask device, or pocket mask, as trained. Perform CPR if necessary. Immediately flush contaminated eyes with gently flowing water. Do not induce vomiting. If vomiting occurs, lean patient forward or place on left side (head-down position, if possible) to maintain an open airway and prevent aspiration. Keep patient quiet and maintain normal body temperature. Obtain medical attention. Chlorinated fluorocarbons (CFCs) and related compounds
SECTION 5: Firefighting measures
Suitable extinguishing media
Suitable extinguishing media: Use water spray, alcohol-resistant foam, dry chemical or carbon dioxide.
Specific hazards arising from the chemical
Excerpt from ERG Guide 126 [Gases - Compressed or Liquefied (Including Refrigerant Gases)]: Some may burn but none ignite readily. Containers may explode when heated. Ruptured cylinders may rocket. (ERG, 2016)
Special protective actions for fire-fighters
In case of fire in the surroundings, use appropriate extinguishing media. In case of fire: keep cylinder cool by spraying with water.
SECTION 6: Accidental release measures
Personal precautions, protective equipment and emergency procedures
NEVER direct water jet on liquid. Do NOT let this chemical enter the environment. Personal protection: chemical protection suit including self-contained breathing apparatus.
Environmental precautions
NEVER direct water jet on liquid. Do NOT let this chemical enter the environment. Personal protection: chemical protection suit including self-contained breathing apparatus.
Methods and materials for containment and cleaning up
ACCIDENTAL RELEASE MEASURES: Personal precautions, protective equipment and emergency procedures: Use personal protective equipment. Avoid breathing vapors, mist or gas. Ensure adequate ventilation. Evacuate personnel to safe areas; Environmental precautions: Do not let product enter drains; Methods and materials for containment and cleaning up: Ventilate the area.
SECTION 7: Handling and storage
Precautions for safe handling
NO open flames. NO contact with hot surfaces. Handling in a well ventilated place. Wear suitable protective clothing. Avoid contact with skin and eyes. Avoid formation of dust and aerosols. Use non-sparking tools. Prevent fire caused by electrostatic discharge steam.
Conditions for safe storage, including any incompatibilities
Fireproof. Keep in a well-ventilated room.Keep container tightly closed in a dry and well-ventilated place. Contents under pressure.
SECTION 8: Exposure controls/personal protection
Control parameters
MAK: 4200 mg/m3, 1000 ppm; peak limitation category: II(8); pregnancy risk group: C
no data available
Appropriate engineering controls
Ensure adequate ventilation. Handle in accordance with good industrial hygiene and safety practice. Set up emergency exits and the risk-elimination area.
Individual protection measures, such as personal protective equipment (PPE)
Wear safety goggles.
Cold-insulating gloves.
Use local exhaust or breathing protection.
no data available
SECTION 9: Physical and chemical properties and safety characteristics
-
Physical state:
1,1,1,2-tetrafluoroethane is a colorless gas with a slight ethereal odor. Vapors are heavier than air. Shipped liquefied under own vapor pressure. Flash point 351°F. Inhalation at high concentrations is harmful and may cause heart irregularities, unconsciousness or death without warning. Liquid contact may cause frostbite. Vapors can replace the available oxygen.
-
Colour:
Colorless gas
-
Odour:
Faint ethereal odor
-
Melting point/freezing point:
-101°C
-
Boiling point or initial boiling point and boiling range:
?26.5°C(lit.)
-
Flammability:
Not combustible. Gives off irritating or toxic fumes (or gases) in a fire.
-
Lower and upper explosion limit/flammability limit:
no data available
-
Flash point:
no data available
-
Auto-ignition temperature:
no data available
-
Decomposition temperature:
no data available
-
pH:
no data available
-
Kinematic viscosity:
0.204 cP at 25 deg C
-
Solubility:
In water, 2.04X10+3 mg/L at 25 deg C (est)
-
Partition coefficient n-octanol/water:
log Kow = 1.68
-
Vapour pressure:
4990 mm Hg at 25 deg C
-
Density and/or relative density:
1.21
-
Relative vapour density:
(air = 1): 3.5
-
Particle characteristics:
no data available
SECTION 10: Stability and reactivity
Reactivity
Decomposes on contact with hot surfaces or flames. This produces toxic and corrosive fumes.
Chemical stability
Stable under recommended storage conditions.
Possibility of hazardous reactions
1,1,1,2-TETRAFLUOROETHANE is chemically inert in many situations, but can react violently with strong reducing agents such as the very active metals and the active metals. Can react with strong oxidizing agents or weaker oxidizing agents under extremes of temperature.
Conditions to avoid
no data available
Incompatible materials
Incompatible materials: Strong oxidizing agents, Alkali metals
Hazardous decomposition products
When heated to decomposition it emits toxic vapors of /flouride/.
SECTION 11: Toxicological information
Acute toxicity
- Oral: no data available
- Inhalation: LC50 Rat inhalation 2,215,000 mg/cu m/4 hr
- Dermal: no data available
Skin corrosion/irritation
no data available
Serious eye damage/irritation
no data available
Respiratory or skin sensitization
no data available
Germ cell mutagenicity
no data available
Carcinogenicity
no data available
Reproductive toxicity
no data available
STOT-single exposure
Rapid evaporation of the liquid may cause frostbite. The substance may cause effects on the central nervous system and cardiovascular system. This may result in cardiac disorders.
STOT-repeated exposure
no data available
Aspiration hazard
A harmful concentration of this gas in the air will be reached very quickly on loss of containment.
SECTION 12: Ecological information
Toxicity
- Toxicity to fish: no data available
- Toxicity to daphnia and other aquatic invertebrates: no data available
- Toxicity to algae: no data available
- Toxicity to microorganisms: no data available
Persistence and degradability
AEROBIC: 1,1,1,2-Tetrafluoroethane, present at 1.44 mg/L, reached 4% of its Theoretical oxygen demand in 28 days using an activated sludge inoculum in the OECD 301D test(1).
Bioaccumulative potential
An estimated BCF of 6 was calculated in fish for 1,1,1,2-tetrafluoroethane(SRC), using an estimated log Kow of 1.68(1) and a regression-derived equation(1). According to a classification scheme(2), this BCF suggests the potential for bioconcentration in aquatic organisms is low(SRC).
Mobility in soil
The log Koc for 1,1,1,2-tetrafluoroethane was reported as 0.91 tested in soil with pH, organic content, silt, sand and gravel at 6.9, 3.2%, 5.7%, 88.1% and 5.3%, respectively(1). According to a classification scheme(2), this log Koc value suggests that 1,1,1,2-tetrafluoroethane is expected to have very high mobility in soil.
Other adverse effects
no data available
SECTION 13: Disposal considerations
Disposal methods
The material can be disposed of by removal to a licensed chemical destruction plant or by controlled incineration with flue gas scrubbing. Do not contaminate water, foodstuffs, feed or seed by storage or disposal. Do not discharge to sewer systems.
Containers can be triply rinsed (or equivalent) and offered for recycling or reconditioning. Alternatively, the packaging can be punctured to make it unusable for other purposes and then be disposed of in a sanitary landfill. Controlled incineration with flue gas scrubbing is possible for combustible packaging materials.
SECTION 14: Transport information
UN Number
ADR/RID: UN3159 (For reference only, please check.)
IMDG: UN3159 (For reference only, please check.)
IATA: UN3159 (For reference only, please check.)
UN Proper Shipping Name
ADR/RID: 1,1,1,2-TETRAFLUOROETHANE (REFRIGERANT GAS R 134a) (For reference only, please check.)
IMDG: 1,1,1,2-TETRAFLUOROETHANE (REFRIGERANT GAS R 134a) (For reference only, please check.)
IATA: 1,1,1,2-TETRAFLUOROETHANE (REFRIGERANT GAS R 134a) (For reference only, please check.)
Transport hazard class(es)
ADR/RID: 2.2 (For reference only, please check.)
IMDG: 2.2 (For reference only, please check.)
IATA: 2.2 (For reference only, please check.)
Packing group, if applicable
ADR/RID: (For reference only, please check.)
IMDG: (For reference only, please check.)
IATA: (For reference only, please check.)
Environmental hazards
ADR/RID: No
IMDG: No
IATA: No
Special precautions for user
no data available
Transport in bulk according to IMO instruments
no data available
SECTION 15: Regulatory information
Safety, health and environmental regulations specific for the product in question
SECTION 16: Other information
Abbreviations and acronyms
- CAS: Chemical Abstracts Service
- ADR: European Agreement concerning the International Carriage of Dangerous Goods by Road
- RID: Regulation concerning the International Carriage of Dangerous Goods by Rail
- IMDG: International Maritime Dangerous Goods
- IATA: International Air Transportation Association
- TWA: Time Weighted Average
- STEL: Short term exposure limit
- LC50: Lethal Concentration 50%
- LD50: Lethal Dose 50%
- EC50: Effective Concentration 50%
References
- IPCS - The International Chemical Safety Cards (ICSC), website: http://www.ilo.org/dyn/icsc/showcard.home
- HSDB - Hazardous Substances Data Bank, website: https://toxnet.nlm.nih.gov/newtoxnet/hsdb.htm
- IARC - International Agency for Research on Cancer, website: http://www.iarc.fr/
- eChemPortal - The Global Portal to Information on Chemical Substances by OECD, website: http://www.echemportal.org/echemportal/index?pageID=0&request_locale=en
- CAMEO Chemicals, website: http://cameochemicals.noaa.gov/search/simple
- ChemIDplus, website: http://chem.sis.nlm.nih.gov/chemidplus/chemidlite.jsp
- ERG - Emergency Response Guidebook by U.S. Department of Transportation, website: http://www.phmsa.dot.gov/hazmat/library/erg
- Germany GESTIS-database on hazard substance, website: http://www.dguv.de/ifa/gestis/gestis-stoffdatenbank/index-2.jsp
- ECHA - European Chemicals Agency, website: https://echa.europa.eu/
Other Information
Do NOT use in the vicinity of a fire or a hot surface, or during welding.Turn leaking cylinder with the leak up to prevent escape of gas in liquid state.